****************************************************************************** dorisreport 03-Nov-2004 13:34:43 Message No 0038 ****************************************************************************** Author: Granier Jean-Pierre Subject: Historic of the on-board JASON transit time used for POE > Dear colleagues, > > Here is the historic of the on-board JASON transit time used in for the POE determination: > > JASON used USO 2 until cycle 91 > From begining to cycle 30 the transit time used was 879.2 E -6 seconde for 400 MHz > Then from cycle 31 to the end of USO 2 ( cycle 90) the transit time used was 873.0 E -6 seconde for 400 MHz > > From cycle 91 JASON use the USO 1 > Then the transit time used for 400 MHz is 879.2 E -6 seconde > And the transit time used for 2 GHz is 327.1E -6 seconde > > Sincerely yours > > Jean-Pierre GRANIER > Please do not reply directly to this message, but send comments and suggestions to IDS.central.bureau@cls.fr