***************************************************************************= *** dorisreport 12-Oct-2021 17:23:11 Message No 5418 ***************************************************************************= *** Author: "Lemoine, Frank G. (GSFC-61A0)" Subject: Submission of gscwd52 series to IDS Data Centers. We have submitted a new SINEX series, gscwd52, to the IDS Data Centers. This series is identical to gscwd50 (prior to the launch of Sentinel-3A), and identical to gscwd51 between the launch Sentinel3A and Sentinel3B. GSCWD52 includes Sentinel3B after 2018-06-06. We note a similar POD performance for Sentinel-3B as for Sentinel-3A. The SLR fits to slr+doris orbits are an average 0.791 cm over 197 arcs from June 2018 to July 2021, with an average of 870 SLR observations and 75221=20 DORIS observations per arc.=20 As with the processing for the other DORIS satellites, the elevation cutoff is 7 degrees for Sentinel3B, and we apply an elevation dependent function. For further information on the modeling with regard=20 to this series, we refer the readers to the description file for this series at the IDS Data Centers, and/or to the following DORISREPORT messages: DORISREPORT Message No: 5416 12-Oct-2021 15:44:55 UTC=20 "Update of gscwd50 SINEX Series". DORISREPORT Message No: 5337 " Technical Description of gscwd51 solution" 06-Jul-2021 17:38:33 UTC.= Please do not reply directly to this message, but send comments and suggestions to IDS.central.bureau@cls.fr