RINEX/DORIS format
This document describes the RINEX DORIS 3.0 format. It is used for the DGXX exchange between the raw data from telemetry, processed by the DORIS Control Centre. This format is based on the RINEX V3.0, “The Receiver Independent Exchange Format”.
DOI, metadata and licence
This product is referenced with a DOI: 10.24400/312072/i04-2026.013
Citation
If you use the document, please cite: "RINEX DORIS 3.0. CNES. Issue X*, year* (DOI: 10.24400/312072/i04-2026.013)"
(* ex: issue 1.7, 2015)
Document version available to the IDS:
| Issue | Date (dd/mm/yyyy) | Notes |
|---|---|---|
| 1.1 | 12/02/2008 | |
| 1.3 | 11/05/2010 | The formulas of frequency shifts are incorrect (§6.16) |
| 1.7 (current) | 28/09/2015 | The expression of frequency shifts in station frequency formulas has been corrected (§6.16) |
Document access
The current version in PDF format is available here and can be seen below: